Optical Transceiver
Products
Home

Optical Transceiver

10G SFP+

10G DWDM SFP+

10G SFP+ DWDM 80KM LC Optical Transceiver 100GHZ

10G SFP+ DWDM 80KM LC Optical Transceiver 100GHZ

  • Product Model:

    ESDxxX-80D(I)
  • Data Rate:

    10G
  • Wavelength:

    DWDM
  • Distance:

    80KM
  • Connector:

    LC
  • Fiber Type:

    SM
  • DDM:

    YES
  • Product Origin:

    China
  • Shipping Port:

    ShenZhen

  • Product Detail

10G SFP+ DWDM 80KM LC Optical Transceiver - 100GHz Grid‌

This compact 10G SFP+ DWDM transceiver enables 80km data transmission over single-mode fiber with 100GHz ITU grid spacing. Operating at 10.3125Gbps across C-band wavelengths (1528.77nm to 1563.86nm), it features LC duplex connectors and SFP+ hot-pluggable form factor.



 Equipped with digital diagnostics monitoring (DDM) and compliant with IEEE 802.3ae standards, it consumes under 1.5W while supporting industrial temperature operation (-40°C to +85°C). Designed for metro networks and data center interconnections, this transceiver delivers reliable performance with 100GHz channel spacing for high-density WDM applications.


  • Up to 11.1Gbps Data Links 
  • Up to 80km transmission on SMF 
  • DWDM EML Laser and APD receiver 
  • Metal enclosure, for lower EMI 
  • 2-wire interface with integrated Digital Diagnostic monitoring 
  • Hot-pluggable SFP+ footprint 
  • Specifications compliant with SFF 8472 
  • Compliant with SFP+ MSA with LC connector 
  • Single 3.3V power supply 
  • Case operating temperature range:0°C to 70°C 
  • Power dissipation < 1.5W







SFP+ CWDM 10KM
SFP+ CWDM 40KM
SFP+ DWDM 40KM
SFP+ DWDM 80KM
SFP+ DWDM Tunable 80KM
10G
10G
10G
10G 10G
1271nm to 1611nm
1471nm to 1611nm 1528.77nm to 1563.86nm
1528.77nm to 1563.86nm 1528.38nm to 1564.45nm
10KM
40KM
40KM
80KM
80KM
LC
LC
LC
LC
LC
SM
SM
SM
SM
SM
DDM
DDM
DDM
DDM
DDM
COM: 0°C ~70°C
EXT: -20°C ~85°C
IND: -40°C ~85°C

COM: 0°C ~70°C
EXT: -20°C ~85°C
IND: -40°C ~85°C
COM: 0°C ~70°C
IND: -40°C ~85°C
COM: 0°C ~70°C
IND: -40°C ~85°C
COM: 0°C ~70°C
IND: -40°C ~85°C




FAQ:

Q1: Can 10G SFP+ LR modules work with single-mode fibers?‌
A1: Yes, standard 10G-LR modules require OS2 single-mode fiber (1310nm wavelength) with 10km reach.


Q2: Can I use 10G BiDi SFP+ for duplex fiber conversion?‌
A2: Yes, BiDi modules (1270nm/1330nm) enable single-fiber bidirectional transmission on existing duplex fiber plants.


Q3: Why do some 10G SFP+ modules require external clock circuits?‌
A3: High-speed modules (e.g., 10G-LR) use ‌CDR (Clock Data Recovery)‌ chips to reduce jitter, requiring precise clock synchronization circuits on host PCB designs.


Q4: Can I plug a 10G SFP+ module into an SFP port?‌
A4: Physically compatible, but ‌electrically incompatible‌ – SFP ports lack 10G SerDes lanes, causing link failure unless switch supports rate adaptation.


Q5: What is difference between SFP and SFP+?
A5: The main difference between SFP and SFP+ is that the SFP+ is used in Gigabit Ethernet applications while SFP is for 100Bse or 1000Base applications. SFP doesn't support 10G transmission data rate, which means they can't be used in the same network.


Q6: What is SFP+ port used for?
A6: SFP + modules are commonly used for Gigabit Ethernet and 10 Gigabit Ethernet connections and can adapt to various application scenarios, including high-speed network connections and fiber optic links.


Q7: How to choose between SR, LR and ER optical modules?‌

A7: SR (Short Reach) for ≤300m multimode, LR (Long Reach) for 10km single-mode, ER (Extended Reach) for 40km+ single-mode applications.


Q8: What are the advantages of 10G SFP+ BIDI?
A8: Key Benefits:‌
Single-Fiber Solution‌ - Uses WDM to transmit/receive on one fiber (e.g., 1270nm/1330nm pairing)
Cost Savings‌ - 50% less fiber usage, 30-40% lower installation costs
Space Efficiency‌ - Doubles port density without new cabling
Applications: areas with limited fiber resources, 5G fronthaul networks, metropolitan area network expansion, and high-density data center interconnection.


Q9: Do 10G modules support DDM/DOM monitoring?‌
A9: A: Yes, compliant modules follow ‌SFF-8472‌ for real-time monitoring of temperature, TX power, and RX sensitivity.


Q10: What is the maximum transmission distance of ETU-Link optical modules?‌
A10: Our modules support from 100m (SR multimode) up to 120km (ZR single-mode), with specific models optimized for 300m, 10km, 40km, 80km and 120km applications.



Leave A Message

If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Related Products
400G QSFP-DD FR4
400G QSFP-DD FR4 2KM LC Optical Transceiver

400G QSFP-DD FR4 2km LC Optical Transceiver‌ The ‌400G QSFP-DD FR4 2km‌ transceiver is a high-performance optical module designed for long-distance 400 Gigabit Ethernet applications. It leverages ‌PAM4 modulation‌ and ‌CWDM EML lasers‌ to achieve ‌2km transmission‌ over single-mode fiber (SMF), complying with IEEE 802.3bs & QSFP-DD MSA standards. Applications:‌ Data center interconnects‌ between remote sites. 5G fronthaul/midhaul‌ networks requiring high-bandwidth, low-latency links. Enterprise and cloud service provider‌ infrastructures scaling to 400G. RoHS compliant‌ and engineered for future-proof networking, this transceiver enables seamless migration to next-generation 400G architectures. QSFP-DD MSA compliant  Compliant to 100G Lambda MSA  400G FR4 Specification compliant  4 CWDM lanes MUX/DEMUX design  8x53.125Gb/s PAM4 electrical inter- face (400GAUI-8)  Maximum power consumption 12W  LC duplex connector  Supports 425Gb/s aggregate bit rate  Up to 2km transmission on single mode fiber with FEC  Single 3.3V power supply  RoHS compliant 200G QSFP56 SR4 100M 400G QSFP-DD SR8 100M 400G QSFP-DD DR4 2KM 400G QSFP-DD LR4 10KM 400G OSFP SR8 100M 200G 400G 400G 400G 400G 100M 100M 2KM 10KM 100M 850nm 850nm 1310nm CWDM 850nm MPO MPO MPO LC MPO MM MM SM SM MM DDM DDM DDM DDM DDM COM: 0°C ~70°C COM: 0°C ~70°C COM: 0°C ~70°C COM: 0°C ~70°C COM: 0°C ~70°C FAQ: Q1: What is 400G QSFP-DD? A1: It is a high-density, hot-pluggable optical module interface supporting 400Gbps data rates, featuring 8 electrical channels for enhanced bandwidth. Q2: What are the main types of 400G QSFP-DD modules? A2: Common variants include SR8 (short-range), DR4/FR4 (intermediate), LR4/LR8 (long-range), and ER4/ER8 (extended-reach), with transmission distances ranging from 100m to 40km. Q3: How does OSFP differ from QSFP-DD?‌ A3: OSFP has a larger form factor and non-compatible electrical interfaces, while QSFP-DD is backward-compatible with QSFP28 modules. Q4:What encoding scheme does 400G OSFP use?‌ A4: Data Rate 53.125Gbps (PAM4) per channel(Maximum power consumption 12W), balancing speed and complexity. Q5: What is the maximum transmission distance for 400G QSFP-DD LR4? A5: The LR4 variant supports up to 10km over single-mode fiber (SMF) using 4x106Gbps lanes, ideal for 5G and cloud interconnects.  (https://www.etulinktechnology.com/400g-qsfp-dd-lr4-10km-lc-optical-transceiver_p330.html) Q6: What is the electrical interface of QSFP-DD? A6: The module converts 8 channels of 50Gb/s (PAM4) electrical input data to 4 channels of CWDM optical signals and multiplexes them into a single channel for 400Gb/s optical transmission. Q7: Does QSFP-DD support digital diagnostics? A7: Yes, it includes DDM (Digital Diagnostic Monitoring) per MSA standards, enabling real-time monitoring of temperature, voltage, and optical power. Q8: What DAC options exist for 400G QSFP-DD? A8: Available configurations include direct QSFP-DD-to-QSFP-DD, or breakout to 2x200G QSFP56/4x100G QSFP56/8x50G SFP56 for flexible scaling. Q9: How does OSFP differ from QSFP-DD?‌ A9: OSFP has a larger form factor and non-compatible electrical interfaces, while QSFP-DD is backward-compatible with QSFP28 modules.

© Copyright: 2025 ETU-Link Technology CO ., LTD All Rights Reserved.

IPv6 network supported

Friendly Links:

易天官网
top

Leave A Message

Leave A Message

    If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

  • #
  • #
  • #